Features
- display : digital and analogue display, 3200 counts and 33-segment bargraph, digit height 15mm
- data-hold function
- DCV (max. 1000V) and ACV (max. 750V) measurements
- ACA and DCA (max. 1000A) current measurements
- max. Ø for conductor : 50mm
- resistance measurements : max. 30Mohm
- frequency measurements : max. 30kHz
- diode & continuity test and backlight
Specifications
- DC voltage : 3/30/300/1000V
- basic accuracy : ±0.8%
- input impedance : -
- maximum input : 1000V
- AC voltage : 3/30/300/1000V
- basic accuracy : ±1.0%
- input impedance : -
- frequency range : -
- maximum input : -
- DC current : 300/600A
- basic accuracy : ±3.0%
- overload protection : -
- AC current : 300/1000A
- basic accuracy : ±2.0%
- overload protection : -
- resistance : 300/3k/30k/300k/3M/30Mohm
- basic accuracy : ±1.5%
- overload protection : -
- capacitance : -
- inductance : -
- frequency : 30kHz
- basic accuracy : ±2.0%
- overload protection : -
- temperature : -
- overrange : -
- continuity buzzer : yes
- transistor test : no
- diode test : yes
- low-battery indication : -
- maximum display : 3200 counts + bargraph
- LCD display size : -
- ranging mode : auto / manual
- data hold : yes
- backlight : yes
- dimensions : 282 x 104 x 47mm
- weight : ±500g
- power supply : 1 x 9V battery
- packaging : -
- accessories : -
- auto power off : -
DCM268
|